Smoke detectors are a critical way to protect your home and family from a fire disaster. I know what I’m talking about - I lost about all my possession to a house fire.
37 years ago, I was a single mom with three kids and had a fire in my newly-rented home. Thank God none of us were harmed but most of our belongings were destroyed including the kid’s school memories, photo albums, and most of our clothes that were waiting to be laundered in the garage where the fire started. Not that many homes back then had smoke detectors. Today, we would never be without them!
There are two basic types of smoke detectors; ionization and photoelectric. Ionization smoke alarms are more responsive to flaming fires while photoelectric smoke alarms respond quicker to smoldering fires. Since we can’t predict the type of fire that may occur, having some of both types of detectors in your home seems to make sense. That’s what we do.
Ionization-type smoke alarms have a small amount of radioactive material between two electrically charged plates, which ionizes the air and causes current to flow between the plates. When smoke enters the chamber, it disrupts the flow of ions, thus reducing the flow of current and activating the alarm.
Photoelectric smoke alarms work in a different way. The alarm aims a light source into a sensing chamber at an angle that is away from the sensor. If smoke enters the chamber and reflects light onto the light sensor, the alarm triggers.
Most building codes state that, for a residential home, there needs to be one smoke detector in each bedroom and at least one smoke detector on each level of a multi-level home.
In today’s episode, we’ll be replacing a “hard-wired” detector - meaning that it is connected to your home’s electrical system just like the lights are. Since these detectors are electrified all the time, why do they need to have batteries? The batteries serve as a power backup source. If there was a fire and your electricity has gone off, the battery would still sound the alarm if smoke is detected by the alarm.
What about the other type of smoke detectors that do not attach to the home’s electrical circuits? There are two types of alarms that run completely on batteries. One uses replaceable batteries that should be replaced at the interval recommended for that system. The other type comes with a 10-year battery encased in the smoke alarm and once the battery’s time is up, you simply discard and replace the whole alarm. We’ll talk more about them in another episode.
For our demonstration, we are using an alarm that is “hard-wired” meaning it’s connected to the house electrical system. In our case, the electrician that wired our house used the standard procedure for smoke detectors so that multiple detectors can communicate when there is a fire.
If your house was wired this way, you will see a colored connecting wire in the bundle of wires in the ceiling and you can connect the colored wire on your new detector to the existing colored wire to establish the connection between all the alarms on that circuit.
When changing out a smoke alarm that is “hardwired”, the first step is to turn off the electricity, at the breaker box, for the room where the smoke alarm is being changed. Use a current tester, after turning off the power, to make sure there is no current before you start the project.
Secondly, remove the old smoke alarm by taking off the wire nuts that are connecting the live wires to the smoke detector wires. You also need to replace the old rim ring with the new one that came with your new detector.
Next, you will connect the new smoke detector by connecting wires white to white, black to black and secure them with the wire nuts. If there is a colored wire in the bundle, connect it to the colored wire on your detector with a wire nut. If there is no colored wire (other than black, white, or green) coming out of the box, leave the cap on the colored wire on the detector. DO NOT connect it to any of the wiring.
Now push all the wires back into the box, and reinstall the mounting ring. Then lift the detector up into place and twist it onto the mounting base.
Once you have connected the new detector, test it with the test button. And now, you’re better protected against the tragedy of fire. And with what you’ve just learned, you can JUST DO IT YOURSELF!
Buy your DFJ T-Shirt, Cap, or Coffee Mug at https.//www.dirtfarmerjay.com/shop
Follow us on Social Media to know when we’re building projects or releasing new episodes!
Hi this is Dirt Farmer Maggie from DirtFarmerJ.com. You know smoke detectors
are a great way to protect your home and your family
from a fire disaster but they have to be changed out every 10 years.
While there's no guarantees that a fire won't start in your home,
smoke detectors are a great way to stack the odds
in your favor. Stay tuned and I'll tell you a little bit about my personal story
with a house fire and we'll show you how to change out a
hardwired smoke detector. Hey Dirt Farmer Maggie here again.
You know before we start showing you how to change out that hardwired smoke
alarm, I promise to share a little bit of my story with you. So here goes.
This was 37 years ago and I was a single mom with three little kids
and we had been living in apartment after apartment after apartment and
finally we found a house to rent. We were so
excited. We moved into it. We had most of our
stuff in the garage. We slept there overnight. We got up the
next morning. I took the kids to baseball games that they were playing in
and as we came home and got into our neighborhood I saw all this commotion
going on and there were cars everywhere. There
were police cars. There were fire engines. There were even tv stations there and I
pulled up to the end of my street and I said to this police officer,
what's going on? I can't even get into my house and he said,
well there's a house on fire down the street and I said,
which house? And he said the one with a big weeping willow tree and I thought
that's my house. Oh my gosh. I pulled my car off to the side. I told
the kids to stay in the car. I ran down the street and the roof of
the house had burned off and it had fallen into the house
and everything was gone. I told you my story today because
I never want to have what happened to me happen to you and your family and one of
the best ways to prevent that is to make sure that your smoke alarm
is up to date and working well. So let's get going.
Now we're going to show you how to replace that hardwired smoke detector.
Okay so the first thing we're going to do is turn off the power for this
circuit which we've done. We've gone in the basement,
flipped the circuit breaker so there's no power here.
Then we're going to dislodge this from the ring
by turning to the left and bringing it down
and then this is the connector that's connecting the wires to the
to the smoke alarm and we're just going to jiggle that
and get it unplugged and now we've got the smoke alarm free.
This is the part that you're going to discard. If you don't want it beeping in
your garbage you're going to want to take the battery out
by opening this taking the battery out and then discharging by pushing this
button until it stops beeping and then you can
throw it away and you won't have to listen to it all night.
So the next thing to do is to remove this ring that is covering the box up
here and the reason you want to do that is to give you as much room as possible
to work and manipulate the wires. So we're going to go ahead and loosen the
two screws right up here and go ahead and pull that off and when
you do now you've got all this up here to work
with. Now we did de-energize these but
just to be safe just in case I made a mistake in the breaker
or something like that we're going to go ahead and
test these wires to make sure they're not hot.
So let's accomplish two things at one time here. So up here
I'm actually going to undo these wire nuts and remove the old connector and
but that's also going to expose these wires where I can use this electrical
tester to make sure that we have no energy
flowing in these wires. Let's get to it. Okay we now have these three wires
all done. The colored wire is for the interconnect system in this. We'll tell
you about that a little bit more in a moment
but this is the power this is the hot and the neutral. So what we're going to
do is we're going to put one lead on the hot
one here and we have no power. Let's try it one more time you'd see a neon light
come on here and that indicator would jump
if we had power. Nothing is happening and you can see here what it would look
like if we did have power running through it when we put it into an outlet.
So we're working safe. Okay so this is the replacement connector and harness
for the new model that we're putting up there and
it's really simple. You just connect black to black,
white to white and in this case we do happen to have red wires hanging out of
the box. That's what the electrician used
although your wiring may have a different color wire for what's called
the interconnect system. The interconnect system allows
one single smoke alarm to detect and then inform so to speak
the other ones on the floor using this wire. If you do not have
a colored wire, in this case it happens to be a red one,
it could be blue, it could be green, it could be anything other than the black
and white hanging out. If you don't have that, do not
connect this red wire to anything. You will cause a
short or damage the equipment. It comes capped from the factory this
way with a little safety cap. In this case we are going to use it but
let's go ahead and wire this up and again
we don't have any power flowing through here so we're just going to line that up
right there same length. Run this right beside it and twist to the right
so it bottoms out very nicely and then what you want to do is
test each time. So by holding here and tugging here to make sure
that it doesn't tug on it securely connected.
Now we're simply going to go to the white wire. Same idea, just run it
down a long line here the same length until it's even right at the end. Slip
the connector up over it, twist until
you feel everything bottom out and it stops
rotating. We're almost there. Okay again I'm gonna tug that is good
and solid. That only leaves our interconnect wire
so what we're going to do here is pull off the little safety
right there. Comes right off, we're ready to go.
We'll just simply put it in line just like we did the others
right here. Slip the wire connector up over
and twist it until it quits rotating. Now the new connector and its harness is
securely attached to the house wiring, the power circuit
and the interconnect system. We're going to now stuff these wires back up in
there and these happen to be 12 gauge wire
so they're a little bit stiff and that's the reason why we pulled that ring off
there so that we have this larger opening to work with.
Let's go ahead and tuck these back in. Okay now that these are all flush up
here let's go ahead and install the new ring over this.
Just tighten them until they're snug. All right now we're just going to reverse
the steps that Dirt Farmer Maggie showed you a little while ago. Here we have
the connector with its harness all connected in the house power and the
interlock or the interconnect system here and so
what we're going to do is take this connector
which only fits one way and we're going to put it
on to the back of this and these can be a little bit persnickety.
Believe me I've tried multiple times. There we go. When it clicks in
you can actually tug and you should tug to make sure this is connected and will
come out. Now because the circuit's off and the
battery has not been energized yet by pulling out this activation tab,
notice the status light. Well it ain't a light. There's nothing there.
This is just a dead unit this part point. So what we're going to do is go ahead and
carefully put those wires back up. You don't want them laying over the top
here and then we're going to rotate this around
in the base until it locks and there it is. It's ready to go.
Let's go turn on the power and you'll see what changes up here.
We have now turned the power back on and as you look under here
you can see there is a green status light meaning house power
is to it. But this will chirp about every 30 to 45 seconds
indicating, there we go, indicating there is no battery power to it yet and
that's because we haven't pulled the tab. So the last
thing to do is pull that tab out and if we open the
door you can see the battery in there and
now it is activated. We still have a little bit
of it where it's chirping where it's getting powered up here
but it is now fully protected. So we'll go ahead and
close it and we have now completed the job. If you found this
video to be helpful please like it and better yet subscribe to our channel. When
you do ring the bell so that every Friday
you'll get notified another great video out there
and while you're at it remember to look for upcoming safety videos on all sorts
of safety devices around the house hosted by Dirt Farmer Maggie and check
out our merch store at www.DirtFarmerJ.com. Great hats,
great shirts, great coffee mugs. Until the next time this is Dirt Farmer Jay
and Dirt Farmer Maggie behind the camera for a few moments
from www.DirtFarmerJ.com. Thanks for watching.