Hello everyone, I'm Rodrigo from
refrigeration courses, everyone,
welcome to another video here on the
channel, guys, in today's video, as you
can see here, we're looking like
Ieda to do the installation, so far, nothing
big, but the BO is here guys, the
bricklayer left the box when he went to do the installation,
it's totally wrong, I'm
going to get closer so you can see and
we're going to record here the step by step
how we're going to solve this problem
to install an air
conditioner type of box when the
box was installed all
wrong but the client asked us to
do everything possible to place the
condenser up there, hidden there
to try to preserve as much of the
aesthetics as possible, so I invite you to
stay in this video until the end and
remember If you want to become a
qualified professional, you want to learn
everything about installation and maintenance of air
conditioning. I have the air
conditioning formula to introduce you to, the link
is below. Okay, so let's go
to the video, good guys,
so you can understand the greatness here.
The problem we're going to have to
solve here is the box, right, this
box is made to receive the two
pipes so we can lower the
copper plus the conduit to lower the
supply underneath, have the drainage, well,
as you can see here, the
drainage doesn't
require a
bricklayer. he didn't leave a
drainage system and here he just left a
tube Centralized on the wall and
still positioned wrong, you see So
what are we going to do, the drain
we're going to have to throw out and here
we're going to have to do some magic
to try to lower the two tubes here, one
1/4 one 3/8 plus the PP cable through this little
guy here
and it was in the middle so I probably think
I'll cut a piece here from the
wall, the part where it will be hidden
to give a better fitting of the
piping here too, so let's see what
will be done with this little guy here,
so guys, so we can start
solving the BO, we start by
doing the main thing, right, passing the
piping all the installation, box,
first thing you have to check, it's a
question of the piping after the
fluid line is ready, so we can
go in and install the evaporator
and the condenser. For us to go down this
piping here, I'm going to need to break it
there to make room for this
piping to go down, okay guys, the
first step was to open the deep there, so
we can free up the mouth of the tube, you know, to
have space for the pipes to go down,
so here, as it's very
deep there, I had to open a
space up here, I'm going to make another
cut here too and I'm going to cut the side
there, here. so I'm going to do
this so I can make the
copper tubes come out as high as possible outside of
this Black tube because then if I
can make it come out higher up
I can have more flexibility with
it down here and I can do a
slightly cleaner job now I'm going to
open these pairs of dough that
are left over, keep cleaning the
box and then I'll make a few more
cuts upwards to get more
space,
okay, so guys, I've made a lot of
space here, the idea is basically as I
said to you want to go up as much as
possible, so here we managed to
widen the tube at more or less this
height with the hole saw, right from the bottom
to the top, here's a tip, a
little bag here, a simple glue
for everything so you can pick up all the dirt
you have doing this to avoid
dirtying the environment and also making it easier
to deliver the job ready, so
you don't need to waste so much
time cleaning, so here I'm going to turn the
camera around and show you everything
we did here was with the hole saw itself,
okay? We
gradually cut the detail there, be very careful
when you open this type of
service because here at the bottom is already the
side there, so if you take the
tape here and measure the thickness of the wall
you will see that this is right here a
very thin shell here is
about 3 cm, so it's
basically just the plaster, if we hit it
there, it will break on the other side and then it will
get worse, right, the customer doesn't want the
machine there, imagine a hole and then it
involves painting and everything else, if it's a
wall that the other side is textured, you've already
seen it, right? It's just downhill, so be
very careful at this point, I'm also going to
turn the camera here so you can see.
So look, guys, looking from above,
we almost didn't get past the the height of the
box right and looking from below, look
at the holes we made with the hole
saw, you can see this way we
can have a little more
flexibility when moving one tube away
from the other here to be able to make
its curve here Now I'm going to
basically do what you guys do another cut
here in the same direction so that
when we position the device and
the client doesn't mind if it needs to
be positioned a little to the
right Okay, but we're going to try to keep
it Centralized But the The intention is to have a
slightly better finish to make room
for PR piping here because if
we don't do this here, as the tubes
will already come out here, we will already bend
when fitting the evaporator, there will be
little space here for the tube And then
the evaporator will be highlighted, you won't be
able to give that
little finish to the ox and continuing here
now we came to the upper part of
LGE to prepare the piping to
send this piping down and as
expected here the
bricklayer also did it so Do what, right? Let's
take a look at PR and you can see how
the bricklayer left the conduit, I think
he thought like that, oh the conduit is
flexible, maybe the copper piping
inside the wall will also snake its way down,
right? That could have been it,
we'll have to break it too, look
guys,
where did the blessed bricklayer leave the
conduit
coming out besides him making this curve, I think
he thought he could leave it the same as the
wires
there, right? It probably starts to
break from this slab
here, to make room for this
copper tube to go down in this direction,
because obviously it's not going to make this
curve,
right? I do
n't think it's bad,
personal, I like it, I'm in the profession
for the love of it, I like working with it
and I like sharing with you
what we find on a daily basis, when
I encounter a service like this that
was done wrong, I like it, okay? giving as
much information as possible because if
a bricklayer, or someone who does this
type of service the wrong way,
is watching my content,
learn and start doing it the
right way, you know, that's why I record it
in so much detail and everything else, sometimes the
We get a little stressed but it's
part of the game let's continue the video
now guys we fixed the
support as you can see here it
needs to be a little off
center these bushings here are the
curtain rod bushings are they centered, the
center of the device will show here, the little
mark that we made. So it will be
more or less here, about 10 cm, the
device will have to be moved a
little to the right because of this
here, but it's going, it will look good here, look like
After we placed the support, the
support had to come down a little bit, there
was a part left here that I marked
that we will have to remove too,
so I'm going to go in with the hole saw here
and I'm going to remove this part here
so I can We have a
work space with the piping, great
guys, support positioned, all the
adjustments made here on the wall and now the
assistant is up there and will send the
piping here, let's see how it
comes out down here, right, this little hole here
guys, oops, I've already seen the light at the end of the
tunnel, this little hole here guys is for
the drain to come out, so we
're going to throw the drain out and then we're going to
try to finish it there so that it looks
nice, well, so let's
take a look here and see how it's going
then. here we have the hole where
a PVC pipe will pass to the drain here
we made a cut here with the hole saw,
same as you can see, always on the
line where the device will hide the
cut so we have space to connect
the space here It was really good, right, it
was better than expected and now we
just have to hope to see if it's going to be good, I've already gotten into
trouble, I'm going to stop recording here and
help the assistant to see if we
can do this well, guys, it's been a little
confusing. Here in the tube, I
changed places with the
auxiliary assistant, it's going to go down there and I'm going to
send it here, I'm going to show you how
we're doing it in this case to
make the two tubes go down there nicely
inside one pipe, just look
guys, so the We applied the
auxiliary finishing tape, it ended up being
enough, he thought it would go
a little further, but there it
surprised me, there's a nice space,
I believe it will go down fine, we just
had to break it down a lot so
we could have space. you need to get the piping
as straight as possible, folks, the
hardest part worked, let's see here, hello, here it
is at 11:30 in the morning, we spent
a lot of time breaking it down here, arranging
everything carefully there, but the piping
is here, connections made from now on.
Now it's routine, everything is fine,
now we're going to start
installing the air conditioning and for those who are
curious to see the final finish, just
stay a little longer here in the video
that will be out shortly. Look guys,
now with the help of the support With a crow's foot,
we can make the
connections, the finishing, then
connect the drain here exactly the way
we thought of doing it later, just
remove the support and fit the evaporator
in its personal place, done with the finishing, here
we put the thermal insulator Everything was
fine, we used PVC tape to finish it off,
but here we have an
aggravating factor, there is no longer a box
to catch the drips and everything else, so
everything we did here with the
thermal insulation, everything was always put on tape
to avoid contact with the piping. with
the external air so as not to generate humidity Here
we put the PVC tape on top here very
tightly as you can see and
now I'm going to use this chrome tape
here as I personally don't like
using it all the time but in
these cases here because of it having
its glue be very sticky, right? I'm going to
cover this here with glue to ensure
that there won't be any air entry,
so as not to have contact with humidity here
at the bottom, right, and at the top,
then we'll do another scheme to
avoid moisture dripping down,
folks, this is the end result of
finishing with tape, it is well sealed, making it
impossible for oxygen to enter
inside so the pipes do not come into
contact with moisture. And this way we
solve the problem of condensation in this
part of the line and it dripping Here's the
drain, guys, how did I do it?
the
thermal insulation of the drain is also
because the water runs cold
here, it would start to condense, the
bottom of the drain
would start dripping from time to time,
so we have already thermally insulated
the drain too and in fact that is
why it it comes with this foam
here guys for thermal insulation
of the drainage too and then we can
solve the problem of it dripping and there wo
n't be any infiltration in the customer's house
Look how it looks after it's
fitted guys, so here's that
part Where did I take it off? side allowed
the piping to fit
perfectly into the drain as well and now
we mount the fairing in place, good
guys line completed here as you can
see, right at the exit here I
always leave a little straight piece in case I
need to pull it there and I make the first
dollar sign and here we have the hole to
send the piping out and the remainder
then we install the
condenser and remove it if necessary,
this way it is doggy for
those who don't know to make it easier and guarantee
the return of oil to the compressor and now
finished, so this part I can
even close it here, right, get out of here,
close the roof everything because
now it's just outside guys, updates guys,
see that letisgo audio
here it's hot, old man, hot, hot
that you don't believe everywhere that
you Costa You burn So you have to
work even with gloves on But let's
continue with the video here, guys,
as it is here, as you can
see, we place the condenser in
front of the pipe outlet, okay? What for?
When do we Look, we can only see
the condenser So I'm going to turn the camera around,
I'm going to show you a little more and
then I'll continue with the installation.
Look, you can see guys, so here, I left it very
low here, so that it's in
front of you, there, it won't work.
Guys, see the machine, it was well
hidden here, the hole remained because
we also put a caulk paste on it
to prevent moisture from entering
inside, the hole always falls
outwards, also to prevent water
from running back inside and here now the
Let's go around and make the connection here,
installation is complete guys, look
how it turned out, now we just put
our sticker here to close it and
look, look, and the clay here too, right,
forgetting and on the outside here,
guys, look The drain looked like this, it
came out there, the client said she's going to paint it
in the color here, so it's well
disguised, we put it here in the
corner, it went down to the bottom and went around here,
and it's going to come out there,
as the client really likes flowers,
she said that Go put a row of flowers
here, it's going to be the most beautiful thing and
now let me talk to you who stayed
in this video until the end because your
interest is knowledge, you're looking to
learn everything about installation,
maintenance, hygiene of air
conditioning, come to inform you that you you
have arrived at the right place, I have
complete training on everything you
need to know to become a
qualified professional to carry out this
and every type of installation, learning
from the basic principle of
window air conditioning refrigeration, which was the father
of air conditioning air conditioning
technology on off, which is the most
common thing we encounter on a
daily basis, and reaching the point of inverter technology,
which is the most advanced, right up to the
floor, ceiling, everything you need to know
to truly be a
qualified professional, in such a way
that an installation you would take this one
seriously, just like me, we teach you
in the air conditioning formula, the link is
below in the description Remembering
that there is a 7-day guarantee, right to a
certificate and a chat group on
Telegram We are together guys Y