CEREC Dental Assistant Training - hands on crown design - setup through positioning

Dave King
65 followers
279 Video Views·Jun 17, 2026
Please like and subscribe for more videos!!
AI Generated·May contain errors
Okay, welcome back. This is Dave King. We're going to go ahead and go through a simple design process
for a molar crown. I'm going to walk you through the process. So, first thing we want to do at
this screen, make sure you have everything set up correctly. Select a single restoration.
We're going to do a crown on tooth number 15, and I don't have any biocopy information. I don't want
to do reference, so I'm going to do biogeneric individual. Then we're going to select the
materials. We're going to use Emax, which is an Ivoclar Vivadent product,
and then we'll go ahead and select the tooth. So, at this point, I'm going to roll over to tooth
number 15, and I could, if I wanted to, activate this smile design, or if I go back in the settings,
I could turn on the articulation function. We're just going to do a standard crown. Now, at this
point, one thing to mention to you, if I wanted to, I could edit this restoration right here
by clicking the edit button, and then I could change what type of design mode we're using.
I could change the materials. I could even change the milling device if we
had multiple milling units. I could also delete it. So, if I go through and I want to do an Emax
here and an Empress crown here, then I'll go back over here. I'm going to edit this now to reflect
Empress, and then I'll add tooth number 14. Now, I know we're only doing 15 right now,
but here you can see 14 populates as an Empress crown, 15 as an Emax. Now, if I wanted to edit
number 15 to be an Empress crown, I can't go over here to edit 15. I have to actually go over here,
click on 15, and then edit it, and I can go in here and change it to an Empress crown if I want
to. I'm not going to do that, however. I'm going to go ahead and delete tooth number 14 because
we're only working on number 15. So, I'm going to hit delete, and I'm going to go next. Now,
I've already taken the images for this restoration, and it's a typodont case, so
it's nothing groundbreaking. Pretty routine stuff. In one of the other videos, we'll talk about
imaging. This is the opposing arch. Here is the upper arch. This is not my prep, but it's a very
nice prep with a retention groove in there and the buckle scan. All right. So, these are pretty
clear images. Nice, clear, crisp images. That's one of the goals we want to focus on with our
imaging is to make sure they're high-quality images. All right. So, let's hit next.
Our first step is to draw the margin. Now, we've already, of course, identified in our
preparation phase where the margin is, but now we just want to tell the computer where that is.
So, first thing to bear in mind is you want to double-click to start,
and you'll notice it defaults to the automatic margin finding setup. There are some docs that
like to go all the way around and outline the margin with the auto margin finder.
Personally, I prefer to do it mostly by myself, so I'll hit spacebar to bring it to manual margin
mode, and you can see that line turns white. If I hit the spacebar again, it'll go back to the
automatic margin finding, but I prefer to use the manual mode. It seems to me to be a little simpler.
So, click, and as you click, the computer is going to automatically curve the lines for us.
If I make a mistake, if I'm out here too far and I want to undo it, you just right-click right here,
and it'll undo your margin. All right, so single clicks to capture where that margin is.
It's a little difficult to see because we've got a white background and a white margin line,
but I'm going to go ahead and outline the margin here. Now, one thing to bear in mind,
you see how I double-click to finish, is whenever you're in doubt, always take the margin wider than
you think it needs to be. Now, this is not perfect, so I'm going to go back and edit this.
I'm going to double-click where I want to start the edit,
and then work my way back around to where the margin is, double-click,
and get to the point where I'm comfortable with that margin. But always remember, you're better
off having too much margin that you can trim off in the post-mill processing phase, or after you've
you are having not enough margin and having to trim the tooth. I'd much rather sacrifice part
of the new restoration than I would sacrifice the tooth itself, if possible. Okay, so let's just
assume we're 100% happy with that particular restoration, or that margination of the crown.
You'll notice as I zoom in, that margin line becomes a lot thinner, and as we zoom back out,
it kind of thickens up, so that we can see a little more clearly, as we're a distance away
from it. Notice as well, the way I'm positioning my hands, this works pretty well for me. Normally,
I use one finger on my left hand, and then my thumb here, and my fingers here. Right,
the right button, if you hold it down and roll, this will pan. In almost every screen, this will
pan. The center button, if you press and hold, this will zoom. Alright, and then this left button,
which I'm going to use my left hand for, will roll, and also select. So if I were to be on
the margin, double-click, it'll select, but it will roll the restoration. So just to recap,
we've got a pan, a zoom in the middle, and a roll. Alright? Okay, so let's say I'm happy with where
this is, the margin, and the next thing we need to do is determine the insertion axis. So this
becomes really critical when we're dealing with multiple restorations, with bridges, or with very
tall preparations. You can see as I'm rolling it over, we're seeing some of this yellow. The yellow
is where the computer is calculating undercut. So we want to be very careful with undercut,
because that can create some issues for us, with regard to the seat of the restoration.
So generally, I want you to line it up with no yellow, if possible.
Also, we want to make sure that we can see as much of this adjacent proximal contact as possible,
so as to ensure that we can get a nice seat when we deliver the crown.
Okay, next we'll go to this preparation analysis step, and you can see we're all green,
a little bit of blue. Here's your key up here on the left, and you can see all this green is
plenty of reduction. Here we're 1.7 or so. Looks like we have plenty of occlusal reduction,
plenty of axial reduction. Shouldn't be an issue with regard to how this seats,
or how much strength we have, how much thickness we have in the restoration.
So the next thing we'll do is get a design. Now at this point, if you did get a proposal
where there was too much, you know, not enough reduction, I guess is what I'm trying to say,
you can go back, re-scan the restoration, and start again. And that's what I'd suggest you do.
If there's not enough reduction, don't cut corners. Back up, lean the patient back,
prep a little bit more, and then re-scan. You don't want to compromise the longevity of the
restoration. Okay, so here's our initial proposal. A couple of things to bear in mind. This blue is
a minimal thickness warning. It does not absolutely mean it's too thin. This is a warning. So when we
turn on our display options, minimal thickness here is you can toggle on and off. And this is
all based on what our parameters are. If our parameters are set to have this axial minimal
thickness at 0.5 millimeters, then anything less than 0.5 is going to show up as being too thin.
So let's take a look at what our parameters are down here. So spacer 200, this is dependent on
your cement thickness. I usually leave mine up at the 200 level. It tends to be a little easier
to see. Acquisal milling offset, this happens after the machine mill, or after it's designed
in the milling phase. This is not something that you can see in your design process. But watch
this area as I alter that acquisal milling offset. See, the positive number increases the height of
the offset, so it's going to mill it taller than you design it. The negative number will mill it
shorter than you design it. Normally we leave ours at about 200, maybe a little less, 150.
That'll compensate for some cement thickness and for some periodontal ligament swelling during and
after the process. Proximal contact strength, this is only for proposal purposes. So what
these three numbers here are, are only for initial proposal purposes. So once you hit
design restoration, that's what determines, this setting is what determines what colors you're
going to get with your initial proposal. So it doesn't really matter beyond the initial proposal.
Some people want the computer to design it all and not to retouch it. I usually go back and
retouch my contacts just a little bit. I like a little bit of yellow. Now I could certainly adjust
that here, so there's a little bit of yellow like I like there. Or I could just leave it where it
was. Occlusal is the same way. This is for proposal purposes only. Dynamic contact strength,
this relates indirectly to the articulation function, which we're not going to talk about
today. Minimal thickness radial, so we're at 1100 microns, 1.1 millimeters, which for me,
that's a little much. I don't need that much reduction. We could go less than a millimeter
there if I wanted to. I'm going to leave it at 1100 just for fun. Minimal thickness occlusal,
1.5. This is all dependent on your material. Now watch what happens. See that the blue is
what I'm changing here. So this blue bubble is the warning that shows up through the restoration
that we were looking at a moment ago. So if I increase this or decrease this,
this will show more blue or less blue. And we can add, bulk out the restoration to hide that blue
or remove it to show more blue. As long as you've reduced appropriately and you have the
appropriate amount of axial and occlusal reduction, this number is not really crucial,
but you want to make sure that you verify that you're well within the manufactured recommendations
with regard to how much you've reduced. So I'm going to hit cancel. We're not going to change
any of these. I'm going to go back to edit. So you can see this little bit of blue here,
and I'm going to increase the translucence of the restoration. So you can see that blue bubble,
the minimal thickness bubble. So you can see we're a little bit outside that blue bubble here.
And again, that was set. If we look at our parameters, we set it at 1100 microns,
which is again, that's a little bit more than you need. So we can actually ignore this. Now,
if I click this off the minimal thickness, you can now see through the restoration and see where
this area is thick. All right. And we can actually go in here if we wanted to and use our distance
tool and measure that, you know, and this is a little bit off. It's a little bit angular.
Depending on where I click, it may not necessarily work well. So that's one tool you can use.
You can also use the cursor detail. So wherever the cursor is, as I roll up here, that'll tell me
my thickness. See that number is rolling up and changing there. It's going to hop way up as I'm
down in that groove. As we go over the occlusal, our height and our fissure height, thickness,
plenty of reduction here. You know, depending on what you want for reduction, it looks like we have
plenty of reduction there. You can actually leave this on while you're designing your restoration.
The cursor details is kind of a helpful guide, but it could get in the way and just take up
screen space. So I'm going to turn my minimal thickness back on. And one thing I will mention
to you is oftentimes if you've turned this off for one restoration and you've gone forward and
finished the whole restoration process, and you go back to another restoration,
this defaults to being off if you've left it off. So make sure that you double check before you mill
that restoration, you double check that your minimal thickness is on so that you can see where
those thin spots may be, areas that you may need to alter. So for me, with the restoration parameter
set at 1100 microns and seeing this, I'm okay with that. But it really depends on the material you're
using, the minimal thickness of the ceramic, whether it's Emax or Empress or whatever it is.
And then also what you prefer is the minimal thickness and how much has been reduced.
So if that's an occlusal area with all that blue, I would be worried. We've got a little blue spot
pinpoint here, which I'll edit here in just a second. We want to be very cautious that we
follow the manufacturer's directions and instructions with regard to minimal thickness.
So let's talk about editing. So a couple of things I will mention to you first is we want
to start editing from big to small. You don't want to start doing fine detail and nuance editing at
this stage. The first thing we want to do is edit big to small. So we want to look at where the
restoration is positioned in relation to the rest of the arch. So for me, the positioning is pretty
good. But just for the fun of it, let's say we wanted to move the restoration around. So a couple
of ways we can do that. If you want a whole lot of control, one of the nice features of the new
software version is this bio jaw function, which is really an advanced function. We're not going
to talk about now in the introductory series, but it is something that is a great tool for us,
which gives us complete control over the design and the shape and the position
with very little computer input. I would leave that alone for now. We'll get to that in one of
the advanced phases. If you want to move this restoration around, a couple of things for you
to consider. I'm going to close these windows so we have more space. There are two ways to get to
your tools. Over here on the right side, you can click and see your tools here. The move tool is
what I would suggest starting with if you need to. So when you click on that, it gives you
rotational, axial, buckle, lingual, distal, all that rotational ability and also positioning.
So I could move the restoration up and down. Another way to get to that tool is to right
click. So I'm using the right click button over the restoration. I'll show you that again. The
right click over the restoration gives you the same tools here as there are here,
with the exception of that one and that one. The same tools, right? So generally speaking,
you've got all these tools that you can use, you can get to by right clicking, okay?
So positioning, if you want to, what I'd suggest is grab in two ways. So if you want to move,
you know, buckle the lingual, you can see how the arrow is highlighted. Mesial to distal,
the arrow is highlighted there. If you want to be able to move in all four
directions, you grab the center square, right? And then you position it wherever you want it.
And then if you want to, we can go ahead and rotate it. If you're not happy with how it is,
you can rotate it, you know, buckle the lingual, match those cusp heights, make sure the
tooth matches the buckle corridor and the palatal corridor. We want to make sure that the tooth is
aligned appropriately.