No Cooling On Labor Day! 20+ Year Old York still Going.

HVAC GUY
26 followers
Tools I Use In My Videos 👇👇👇
https://www.amazon.com/shop/hvacguy
Found compressor running, but not condenser fan motor. Problem turned out to be motor. Replaced it, and checked operations. System is old, but still doing just fine. #hvac #hvaclife #fieldpiece #usmotors
AI Generated·May contain errors
Video Summary
AI GeneratedA technician diagnoses and repairs a non-functional condenser fan motor in a 25-year-old HVAC system. After determining that the capacitor is functional but the motor is seized and overheating, the technician replaces the old motor with a higher-horsepower alternative and installs a new dual capacitor to restore system cooling.
Looks like you got one right here.
I already found the problem outside, so I'm going to...
It seems
like...
Was it cooling pretty good before it stopped?
I did not catch this on film,
but the condenser fan motor was not running.
And I snatched
this out.
I
can't
hardly
see.
Thank God there's not a bunch of wasp on that.
I think it's hot.
I don't see the
cover to it, though.
It's not right offhand.
But
first,
let's...
The bearings are stiff on that motor.
A little bit.
one way you don't always have to check to see
if um you well you do have to check to see if it's
getting power but if the motor's hot
and that's smoking hot you'll know it's getting power so at
this point
all we got
to do is
check that
capacitor
maybe it's
just me
but it
looks like
i got two
brown wires but this one only has one spade on it
so that's my fan
there we
go five
microfarads
it took
a little
while
but it
got there
we'll check
with this one
two point eight
so the
capacitor
is good we need
a new motor
this thing
is in
this
is in
bad
shape
i'll
mess
with
that
plug
this
must
be
from
laundry
or
something
right
here
by the air
this is
clearly
an
original
motor
horsepower
looks
like 1/12
amps 0.5
looking
for
rpm rpm 10
50. all right
so we're going
to use
the lowest
horsepower
1075 i got i
think i can
unplug this i'll see
if i can pull it up
from here replace
this with a quarter
horsepower i know
this
is 1/12 but that's
what we're going
with nope going
the wrong way
this motor's hot
right here i can
feel the heat
coming off of
it how about
that we'll use
this again we
just got a
red black and
brown
these
are hot
using
one of
these
us
motors
1860s
basically
i use
it
for a
quarter
horsepower
and
anything
less
i've
had
good
results
we'll
refer
back
to
that
in
a
minute
i
didn't
show
but
the plugs are in the back side of this motor
on the top the little rubber plugs down here the
holes are
open so
it's going
to be able
to drain
out i
think i'm
going to
replace
the whole
dual
capacitor
on this
instead
of just
providing
a new
single
capacitor
all
right
we want
this
to turn
this way
which is clockwise lead
in this clockwise rotation
lead in means we gotta swap them
don't
try
to
use
it
though
all
right
what
i
do
with
that
plug
here
we
go
i
have
discontinued
the ground
i'm taking
it off cut
this a little
bit shorter
black to black
as you'll see
we've got
got four wires here and three here i think i've shown
y'all how to do this before but this is
this red is my run
these two right
here are the same
run and run
this is my brown
which is start
from the
capacitor all
right let me get
some wire nuts
because
it's hard
to distinguish
which one
is which
both of
these are
brown put
these up
right now
run to the top
of my
contactor
i know it says
common on the
capacitor
but that's wrong
fire it up
forgot to read
amp draw on that
box
amp
draw
1.5
rotation
real
quick
so
that
fan
is
doing
good
22
system
that's
high
suction
it's
about 90 degrees
in there i'm not
really sure how
to tell what year
this is but this
is 25 year old
system
still
doing
fine
that's
it
I
wish
I
knew
where
the
to
that
was
I'll
quote
him
a
new
disconnect it's probably gonna wait though